Specifications

> 1 2 <
Nominal voltage
S
witching capacity
Battery backup
C
ontact
O
wn consumption
Memory spaces
Maximum recommended load
Incandescent
Fluorescents
Low voltage halogen
Halogen (230 Va.c.)
Low consumption lamps
Accuracy
Programming
Minimum operation time
Manual control
Model for outside
Installation
Protection type
Operating temperature
Features
Dimensions
230 Va.c. / 50Hz.
1
6(4) A 230 Va.c.
Without battery back up
-
1
, 6 VA (1, 5 W approx.)
-
3500 W
Not suitable
2250 VA
3500 W
No suitable
Depends on the net frequency
Lateral sphere
D T15 - D T30: Daily
S: Weekly
D T15: 15 min. D T30: 30 min.
S: 1 h.-45 min.
Automatic - Off - On
No
Schuko 4, 8 mm socket type
IP 20
0°C to +60°C
Children protection
230 Va.c. / 50Hz.
1
6(4) A 230 Va.c.
Without battery back up
-
1
, 6 VA (1, 5 W approx.)
-
3500 W
Not suitable
2250 VA
3500 W
No suitable
Depends on the net frequency
Front sphere
D T15 - D T30: Daily
S: Weekly
M-60 - M 150 - M 900: Countdown
D T15: 15 min. D T30: 30 min.
S: 1 h. 45 min. M 60: 0-60 min.
M 150: 0-150 min. M 900: 0-900 min.
Automatic - Off - On
Domo Intemperie D T15, D T30 and S
Schuko 4, 8 mm socket type
IP 20 (IP 24 outdoor models)
0°C to +60°C
Children protection
120 or 230 Va.c. / 24 or 48 Va.c. /d.c. / 50-60 Hz
1
6(10) A / 230 Va.c.
c
os
j =
1
1 year without battery (Lithium CR2032)
A
gSnO
2
C
hangeover
6
VA (1W approx)
32
3000 W
180 W
1000 VA
2500 W
200 W
< ± 1 s/day at 23 ºC
Digital
Pulse programming (1 to 59 s), cycles,
holiday, change s/w.
1 second
Automatic-Off-On
No
Schuko 4, 8 mm socket type
IP 20
-10 ºC to +45 ºC
Children protection
CONTROL
DOMO /
DOMO INTEMPERIE
TEMPO +
> Features
>
PLUG-IN TIMERS
37
55
110
62
55
110
49.537
69
38.537
84
> D
escription
Timer switch for plug in devices, are useful in offices or domestic applications. Analogue, digital and even
water prove models.
Weight: 173 gr. Weight: 184 gr. Weight: 192 gr.