Installation Manual
Standard Mounting Method
1. Use the template provided to determine the correct location and
size of the mounting holes for both the door and frame header.
Ensure that the door opens away from the Maglock. In the case of
a single door, the Maglock should be positioned as close as
possible to the vertical section of the door jamb. Drill the door
and frame as indicated.
2. Loosely install the mounting plate using two of the supplied
Philips head mounting screws in the elongated slots. Attach the
Maglock to the mounting plate.
3. Using a hammer, lightly tap both roll pins into the armature plate
until they are secure. Before installing the Hex Nut, the hole in the
door may need to be drilled or tapped.
4. Using the components shown in the image to the right, mount the
armature to the door. Make sure that the armature plate is not
overtightened and that it is installed as shown in the following
diagram. The armature plate must be free to self-align with the
door.
Mounting Plate
21
3
4
Hexnut Bolt
Door Spacer
Rubber
Washer
Armature
Screw