Hardware installation2–85
Optocoupler (command input) Relay (status output)
Event Type Port
No. Operation
Port
No. Operation
A Bus on–air 0 Level–based. Closed = A is on–air
B Bus on–air 1 Level–based. Closed = B is on–air
Transition Completed 2 Pulse–based. Triggered = transition complete
Bypass 3 Level–based. Closed = in Bypass
Auto Defeat 4 Level–based. Closed = auto defeat is enabled
Segment Timer Reset 5 Pulse–based. Triggered = timer is reset
Key 1 In 6 Pulse–based. Trigger = Toggle Key 1 6 Level–based. Closed = Key 1 is on
Key 2 In 7 Pulse–based. Trigger = Toggle Key 2 7 Level–based. Closed = Key 2 is on
Key 1 Next 8 Pulse–based. Trigger = Toggle Key 1 Next 8 Level–based. Closed = Key 1 Next is on
Key 2 Next 9 Pulse–based. Trigger = Toggle Key 2 Next 9 Level–based. Closed = Key 2 Next is on
Mix 1 In 10 Pulse–based. Trigger = Toggle Mix 1 In 10 Level–based. Closed = Mix 1 is on
Mix 2 In 11 Pulse–based. Trigger = Toggle Mix 2 In 11 Level–based. Closed = Mix 2 is on
Mix 1 Next 12 Pulse–based. Trigger = Toggle Mix 1 Next 12 Level–based. Closed = Mix 1 Next is on
Mix 2 Next 13 Pulse–based. Trigger = Toggle Mix 2 Next 13 Level–based. Closed = Mix 2 Next is on
Same Background 14 Pulse–based. Trigger = Toggle Same Back. 14 Level–based. Closed = Same Backgrnd is on
Preroll 15 Pulse–based. Trigger = Preroll
Take 16 Pulse–based. Trigger = Take
Fade 17 Pulse–based. Trigger = Fade
Silent 18 Pulse–based. Trigger = Silent
Abort 19 Pulse–based. Trigger = Abort
GPI/O Disable 20 Level–based. Energized = Disable
Select System Disable 21 Level–based. Energized = Disable
Select System 1 25 Pulse–based. Trigger = Select System 1
Select System 2 26 Pulse–based. Trigger = Select System 2
Select System 3 27 Pulse–based. Trigger = Select System 3
Select System 4 28 Pulse–based. Trigger = Select System 4
Select System 5 29 Pulse–based. Trigger = Select System 5
Select System 6 30 Pulse–based. Trigger = Select System 6
Select System 7 31 Pulse–based. Trigger = Select System 7
Select System 8 32 Pulse–based. Trigger = Select System 8
Select System 9 33 Pulse–based. Trigger = Select System 9
Select System 10 34 Pulse–based. Trigger = Select System 10
Select System 11 35 Pulse–based. Trigger = Select System 11
Select System 12 36 Pulse–based. Trigger = Select System 12
Select System 13 37 Pulse–based. Trigger = Select System 13
Select System 14 38 Pulse–based. Trigger = Select System 14
Select System 15 39 Pulse–based. Trigger = Select System 15
Figure 2–58. MI 3040IO port assignments. For a discussion of Pulse–based vs. Level–based operation, see page 2–84.