Installation manual

270 Hardware installation
Sync Reference Cables
Sync reference signal requirements are as follows:
Unit
Sync required Type Notes
AVP 3500/4000 Analog Video Processor none
DVP 3500/4000 Digital Video Processor video
terminating
HDVP 3500/4000 HD Video Processor HD trilevel
(recommended)
looping 1. Must be compatible with input
HD signal type selected with
DIP switch S4 (see page 222).
2. Normal black burst may be used
in HD mode, but frame rate
must be exactly equal. Timing
jitter performance is not speci-
fied and not guaranteed when
using SD sync for HD opera-
tion.
AAP 3500/4000 Analog Audio Processor video
looping
DAP 3500/4000 Digital Audio Processor video
or audio looping See discussion on page 226.
AAB 3500/4000 Analog Audio Backup
Switcher
video
terminating
DAB 3500/4000 Digital Audio Backup
Switcher.
video
or
video + audio
looping/ter-
minating
See discussion on page 249.
MCC 3500/4000 Control Console video
looping
VM 3000 Control System video
looping VM3000 not supplied with
standalone systems.
SI 3000 Control System video
looping
MI 3040 General Purpose / Tally Interface none
RPP Redundant Processor Power Supply none
SD3X Status Displays none
DVE Option video
looping Ycable supplied with system
Although any constant APL color test signal may be used for sync, the preferred video reference signal is analog black burst.