Installation manual
2–70 Hardware installation
Sync Reference Cables
Sync reference signal requirements are as follows:
Unit
Sync required Type Notes
AVP 3500/4000 Analog Video Processor none
DVP 3500/4000 Digital Video Processor video
†
terminating
HDVP 3500/4000 HD Video Processor HD tri–level
(recommended)
looping 1. Must be compatible with input
HD signal type selected with
DIP switch S4 (see page 2–22).
2. Normal black burst may be used
in HD mode, but frame rate
must be exactly equal. “Timing
jitter” performance is not speci-
fied and not guaranteed when
using SD sync for HD opera-
tion.
AAP 3500/4000 Analog Audio Processor video
†
looping
DAP 3500/4000 Digital Audio Processor video
†
or audio looping See discussion on page 2–26.
AAB 3500/4000 Analog Audio Backup
Switcher
video
†
terminating
DAB 3500/4000 Digital Audio Backup
Switcher.
video
†
–or–
video† + audio
looping/ter-
minating
See discussion on page 2–49.
MCC 3500/4000 Control Console video
†
looping
VM 3000 Control System video
†
looping VM–3000 not supplied with
stand–alone systems.
SI 3000 Control System video
†
looping
MI 3040 General Purpose / Tally Interface none
RPP Redundant Processor Power Supply none
SD–3X Status Displays none
DVE Option video
†
looping Y–cable supplied with system
†
Although any constant APL color test signal may be used for sync, the preferred video reference signal is analog black burst.