Installation manual
2–64 Hardware installation
T
T
T
One 10Base2 segment:
185 m (607 ft) max.
30 nodes max
R
T
Figure 2–45. LAN cable lengths
Ungrounded
50–ohm terminator
BNC T
Repeater/bridge=
=
=
See notes
All BNC Ts must be
directly on panels
Additional
10Base2 segment
R
Note 1: The individual sections that make up
the 10Base2 cable (those pieces of cable that
run between adjacent nodes) must be at least
1 m (40 inches) long.
Note 2: Hewlett–Packard recommends avoid-
ing 10Base2 cable sections that are multiples
of 5 meters. Especially avoid sections with a
length of:
Meters Feet
5 16.4
10 32.8
15 49.2
20 65.6
25 82
Note 3: All BNC Tees must be equipped with
insulating covers. See Figure 2–47.
See page 2–63 for additional guidelines.
Video Processing Unit
Audio Processing Unit
Audio Processing Unit
Media
converter
or hub
Jupiter file
server
10/100BaseT
LAN
T
10Base2 LAN
10Base2 LAN
10Base2 LAN