Installation manual

Hardware installation237
Note: Be sure the audio sources match connectors numbers with the corresponding video sources.
For example, if VTR1 video is connected to video IN 1, then the audio from VTR1 must be con-
nected to audio IN 1.There is no provision for split switching.
If a second or third AAP processor is used, connect the left and right outputs of the second processor to CH3
IN 0 and CH4 IN 0. A third AAP would connect to CH5 IN 0 and CH6 IN 0. Connect additional sources of
your choosing to CH3, CH4, CH5, and CH6 inputs 1 through 15 if applicable.
8. When an internal CE 300 Controller card is used (the usual case), connect the MPK port on the back of the AAB
to the desired control panel(s):
If this is a single channel Saturn MCS system, this will probably be the built in Select button group on
the MCC 3500/4000 console.
In a multichannel system, the Select panel is used for delegation of the MCC, and other control panels
will be required to operate the Backup Switcher. A CP 300/310/320/330 control panel may be used for
this purpose.
9. Set the DIP switch for the Select button group on the MCC as follows:
a. Lift up the console top. With power off, locate MPK (Select) panel DIP switch package S1. This is an 8posi-
tion switch on the righthand edge of the console.
b. If the Select button group will be used to operate the backup switcher:
(1) Set for CE 300/SC 400 Control (switch 8 ON). See Figure 237 on page 252.
(2) Set the panel type for type 3 (switch 6 and 7 both ON).
(3) Set the output number (usually zero, as described in Step 2 above; in which case switches 1 through 5 are
all OFF).
c. If the Select button group will be used for delegation, set for nonCE 300 Control (switch 8 OFF). (If
switch 8 is OFF, all other switches are ignored.) See Figure 237 on page 252.
d. Close console and repower.
10. If a CP 300/310/320/330 control panel is being used to operate the backup switcher, check the control panel DIP
switches (beneath an access cover on the rear of the panel):
a. Set for CE 300 Control (switch 8 ON).
b. Set the panel type:
CP 300 and CP 330 (type 0); switches 6 and 7 both OFF.
CP 310 (type 1); panel; switch 6 ON, switch 7 OFF.
CP 320 (type 2); switch 6 OFF, switch 7 ON.