 Thetestwillbecarriedoutwithin1monthafterstorageunlessotherwisestated.
8.2 InstrumentsandDevicesforMeasurement

8.2.1 TheDCvoltmeterwillbeusedtocarryoutvoltagemeasurementthatcanmeasurefrom0V
 to4V.Theaccuracyofthevoltmeterwillbe+/1mVoritwillbemoreaccurate.Theinput
 impedancewillbemorethan10Mohm.
8.2.2 Alltheresistanceoftheexternalcircuitloadresistancewillbecomprisedandthetolerance
 willbewithin0.5%.

8.2.3 Thecaliperwillbeusedtoconductdimensionmeasurementandtherangeformeasurement
isfrom0mmto150mm.Theaccuracyis5/100mmormore.
8.3 Testingsystems
8.3.1 Dimensions
 Thecaliperisusedastheinstrumentformeasurement.

8.3.2 Appearance
Thevisualinspectionisapplied.

8.3.3 Opencircuitvoltage
TheDCvoltmeterisusedtomeasurethevoltagebetweenbothterminals

8.3.4 ServiceLife
Thebatterysamplesarekeptundertheconditionoftemperatureof20+/5deg.Cforover
12 hours.The battery samples will be discharged persistently through the dischargeload
mentionedin Table 1.The discharge test will beconducted tillthedischarge
voltage falls
down to not less than the final voltage specified in Table 1.The discharge time is the
servicelifewhilethedischargevoltageremainsabovethefinalvoltageasstated.
8.3.5 Resistanceofelectrolyteleakage
Thevisualinspectionisusedforcheckingthestateoftheleakage.The
batterywillbeput
30cmawayunder 40wattfluorescentlampatonemeterabove.
9. Others
 SubjecttheRoHSdirective,thisbatterydoesnotcontainthefollowingchemicalsubstance:
 lead,mercury,cadmium,hexavalentchromium,bromic,
 fireretardants(polybrominated biphenyl(PBB),polybrominateddiphenyl(PBDE)