Datasheet
Page6of13
CR2450 ‐ 650231
Thetestwillbecarriedoutwithin1monthafterstorageunlessotherwisestated.
8.2 InstrumentsandDevicesforMeasurement
8.2.1 TheDCvoltmeterwillbeusedtocarryoutvoltagemeasurementthatcanmeasurefrom0V
to4V.Theaccuracyofthevoltmeterwillbe+/‐1mVoritwillbemoreaccurate.Theinput
impedancewillbemorethan10Mohm.
8.2.2 Alltheresistanceoftheexternalcircuitloadresistancewillbecomprisedandthetolerance
willbewithin0.5%.
8.2.3 Thecaliperwillbeusedtoconductdimensionmeasurementandtherangeformeasurement
isfrom0mmto150mm.Theaccuracyis5/100mmormore.
8.3 Testingsystems
8.3.1 Dimensions
Thecaliperisusedastheinstrumentformeasurement.
8.3.2 Appearance
Thevisualinspectionisapplied.
8.3.3 Opencircuitvoltage
TheDCvoltmeterisusedtomeasurethevoltagebetweenbothterminals
8.3.4 ServiceLife
Thebatterysamplesarekeptundertheconditionoftemperatureof20+/‐5deg.Cforover
12 hours.The battery samples will be discharged persistently through the dischargeload
mentionedin Table 1.The discharge test will beconducted tillthedischarge
voltage falls
down to not less than the final voltage specified in Table 1.The discharge time is the
servicelifewhilethedischargevoltageremainsabovethefinalvoltageasstated.
8.3.5 Resistanceofelectrolyteleakage
Thevisualinspectionisusedforcheckingthestateoftheleakage.The
batterywillbeput
30cmawayunder 40wattfluorescentlampatonemeterabove.
9. Others
SubjecttheRoHSdirective,thisbatterydoesnotcontainthefollowingchemicalsubstance:
lead,mercury,cadmium,hexavalentchromium,bromic,
fireretardants(polybrominated biphenyl(PBB),polybrominateddiphenyl(PBDE)