Datasheet

Page5of13
CR2450 650231
6.Servicelife
Loadresistance 7,500ohms
Dischargemethod 24hours/day
Endvoltage 2.0V
Minimumduration(Initial) 1450hours
Minimumduration(After12months
storage)
1421hours
Initialtest : Atestcommencingwithinonemonthafterdelivery.
Storedtest : Atestconductedafter12monthsstorageunderthespecifiedconditionsafterdelivery.
7.Dischargecharac teristicsonload
VoltageVLoad7.5KΩ
3.5

3.0
20
2.5
1060
2.0
050010001500
DischargeTimeHours
8.BatteryTesting
8.1 Temperature andHumidity

8.1.1 ConditionsofMeasurement
The battery will be measured under the conditions of temperature of 20+/5 deg. C and
relativehumidityof65+/15%unlessotherwisestated.

8.1.2 ConditionsofStorage
 Thesamplebatteriesfortestingwillbestockedundertheconditionsoftemperatureofless
 than25deg.Candrelativehumidityoflessthan75%.