Datasheet
Page3of13
CR2450 ‐ 650231
4. Mainreference
Item Unit Figures Condition
NominalVoltage V 3.0 OnlyappropriatedforCRBattery
NominalVolume mAh 580
7.5kΩcontinuouslydischarge
load
Instantaneousshort‐cutcirc uit mA≥350
time≤0.5′
OpencircuitVoltage V 3.25‐3.45 AllCRBatteryseries
Storagetemperature
℃
0‐40 AllCRBatteryseries
Appropriatedtemperature
℃
‐20‐60 AllCRBatteryseries
Standardweight g Appro6.25 Onlyappropriatedforthisitem
Dischargeoflife %/yr 3 Onlyappropriatedforthisitem
QuickTest
Useoflife
Initial
H
≥193.3
Dischargeload1kΩ,Temperature
20±2℃,undertheconditionof
relatedhumidity≤75%
After12
months
h
≥189.2
Remark1:Theelectrochemistryofthisproduct,dimensionareunderIEC60086‐1:2007standard
(GB/T8897.1‐2008,Battery ,Relatedto1
st