CR2450 ‐ 650231 Customer acceptance Lithium Manganese Dioxide Battery CR2450 : Date : Checked : Date : Approved: Date : Typed Customer admit signature: 1. Approved : Date : Scope These specifications are applicable to the manganese dioxide lithium batteries.
CR2450 ‐ 650231 3. Battery Type and Performance 3.1 Type CR2450 3.2 Nominal voltage 3.0 volts 3.3 Nominal discharge capacity 580mAh (Load: 7.5K ohms, End voltage 2.0V) 3.4 Outside dimensions As per drawing attached 3.5 Standard weight 6.25g 3.6 Guarantee 1 year (at the temperature of less than 25 deg. C and the relative humidity of less than 75%.) Will be free from flaw, stain, deformation, uneven tone, electrolyte leakage and other defects which impair the value of the commodity.
CR2450 ‐ 650231 4. Main reference Item Unit Figures Condition Nominal Voltage V 3.0 Only appropriated for CR Battery Nominal Volume mAh 580 7.5kΩ continuously discharge load Instantaneous short‐cut circuit mA ≥350 time≤0.5′ Open circuit Voltage V 3.25‐3.45 All CR Battery series Storage temperature ℃ 0‐40 All CR Battery series Appropriated temperature ℃ ‐20‐60 All CR Battery series Standard weight g Appro6.
CR2450 ‐ 650231 5.Specification of product and Test method Exception for specified explanation, all tests should process under below conditions: (1)Environment Temperature :Temperature 20±5℃ Test items (2)related humidity:under 60±15% Test Methods Standard Use of caliper under precision is 0.02mm 1. Dimension or more precise,to avoid short‐circuit, diameter(mm) :24.50(‐0.20) insulated materials should be put on the height(mm) :5.00(‐0.20) vernier caliper during test. Precision is 0.
CR2450 ‐ 650231 6.Service life Load resistance 7,500 ohms Discharge method 24 hours/day End voltage 2.0V Minimum duration (Initial) 1 4 5 0 hours Minimum duration (After 12 months storage) 1 4 2 1 hours Initial test Stored test : : A test commencing within one month after delivery. A test conducted after 12 months storage under the specified conditions after delivery. 7.Discharge characteristics on load Voltage(V) Load 7.5KΩ 3.5 3.0 20℃ 2.5 ‐10℃ 60℃ 2.
CR2450 ‐ 650231 The test will be carried out within 1 month after storage unless otherwise stated. 8.2 Instruments and Devices for Measurement 8.2.1 The DC voltmeter will be used to carry out voltage measurement that can measure from 0V to 4V. The accuracy of the voltmeter will be +/‐1mV or it will be more accurate. The input impedance will be more than 10M ohm. 8.2.2 All the resistance of the external circuit load resistance will be comprised and the tolerance will be within 0.5%. 8.2.
CR2450 ‐ 650231 Page 7 of 13
CR2450 ‐ 650231 Page 8 of 13
CR2450 ‐ 650231 Page 9 of 13
CR2450 ‐ 650231 Instructions for Usage and Safety The battery consists of lithium, organic, solvent, and other combustible materials. Proper handling of the battery is of utmost importance; otherwise, the battery could lead to distortion, leakage (accidental seepage of liquid), overheating, explosion, or fire and cause bodily injury or damage to equipment. Please strictly comply with the following instructions to avoid the occurrence of accident.
CR2450 ‐ 650231 battery should not be soldered directly to equipment which it must be done only on tabs or leads. The temperature of soldering iron must not be over 50 degree C and the soldering time must not be more than 5 seconds; it is important to keep the temperature low and the time short. The soldering bath should not be used as the board with battery could stop on the bath or the battery could drop into the bath.
CR2450 ‐ 650231 Using and setting protective resistance In order to refrain from changing the battery by large surges of current when the diode is failed, the protective resistance should be applied. It is recommended to adjust the protective resistance to make the maximum current not over the figures as stated in the table.
CR2450 ‐ 650231 SPECIFICATION FOR INSPECTIONS It is guaranteed that this specification of the inspections will be fulfilled by our products 1. Quality Standard The product specification will be conformed. 2. Unit of Inspections One battery will be taken as one unit of inspection. 3. Definition of Lot A batch of products that are manufactured by the same production lines with the same lot code mark. 4. Test Method The product specification will be conformed. 5.