Datasheet
3
[Table 3]
Test Item Temperature Start Period Storage Period
Testing
Conditions
20±2 Above 320h Above 270h
Operating Life
0±2 Above 260h Above 240h
15KΩ loaded
continuously
discharge to
end voltage of
2.0V
5High Temperature Storage Operating Life
High Temperature Storage Operating Life is measured according to
4.36should satisfy the requirements of Table 4.
[Table 4]
Test Item
Storage
Temperature
Storage
Time
Discharge
Time
Testing Conditions
High Temperature
Operating Life
60±2 20 days Above 270h
15KΩ loaded continuously
discharge to end voltage
of 2.0V
6Leakage Property
Leakage property is measured according to 4.37should satisfy the requirements
of Table 5.
[Table 5]
Test Item Requirements Test Conditions
Leakage Property No leakage
Temperature 45±2
Relative Humidity
≤75%RH
Storage 30 days, Visual
observation
7Leakage property under over-discharge
Leakage property under over-discharge is measured according to 4.38,
should satisfy the requirements of table 6.
[Table 6]
Test Item Requirements Testing Conditions
Leakage property under
over-discharge
No Leakage
Over-discharge
Time5hoursDischarge
time after reached end
voltage of 2.0V
4. Test
4.1 Testing Conditions
1Temperature and Relative Humidity
Without any other specified special conditions, test conditions are :
Temperature 20±2Relative Humidity 45 -75% RH.
2Battery Storage
Battery to be inspected should be stored at temperature 20±2Relative
Humidity 45 -75%RH.
4.2 Testing Equipment
1Tools
Vernier of precision not less than 0.02mmruler or thickness test equipment