E. How to use OVERRIDE functions
619-modeTimer is designed with 
2 Override function, so as to widen its usage upon 
practicable application. Override function 
is effective only when Timer is running 
under AUTO mode.
Temporary-Override --- Follow procedure below:
Condition-1  When Timer’s output status is “ON”
Pressing MANUAL key, to move indicator 
from “ AUTO “ to “ OFF”, Timer output shall turn 
to “ OFF” status, programs overrided. 
Pressing MANUAL again to switch Timer status 
to “ AUTO “, Timer’s output shall continue 
maintaining “ OFF “. Timer shall resume its automatic 
operation when next program(event) calls for “ ON “. 
(With next opposite set point).
Condition-2 When Timer’s output status is “OFF”
Pressing MANUAL key, to move indicator from 
“ AUTO “ to “ ON”, timer output shall turn to “ ON” 
status, programs overrided. 
Pressing MANUAL again to switch Timer status
to “ AUTO “, Timer’s output shall continue maintaining 
“ ON “. Timer shall resume its automatic operation 
when next program(event) calls for “ OF “. 
(Until next opposite set point)
Random-Start-Up Override –  Press and hold DAY 
key and then press MIN key. There shall be a symbol
shown on left corner of LCD screen, to indicate 
this Override in executing. 
When this Override is being executed, the original 
programs will be stopped, and once every 
10 to 120 minutes Timers shall automatically 
turn its output to “ON” status. 
In practicable application which is applied to 
home-use, this Override function also called Anti-Burglar 
Override.
Once again to press and hold DAY key, and then 
press MIN key shall stop this Override. 
PP
Remark:
1. For voltage and electrical RATING information,
 please refer to the markings on the back of timer.
2. See the back of timer for proper wire connections.
3.Timer may need to be connected to power source
 in order to set the program.
Follow graphic description below & Refer to section of
Descriptions to Model Code on this instruction-sheet
upon proceeding electrical wiring.
PROPOSED APPLICATION
DANGER
Electric Shock Or Fire Hazard
READ ALL WIRE SIZING, VOLTAGE REQUIREMENT AND SAFETY
DATA AVOID PROPERTY DAMAGE AND PERSONAL INJURY
Output of Timer is 
produced with screw-on
type to provide 
convenient electrical wiring
upon mounting Timer on
equipments.
This Timer provides Volt-Free output contact only. 
NO
NC
120/240 Vac 24Vac/Vdc 12Vdc
35.2
PROGRAMMING THE TIMER #2 