Potentiometer:
47k linear
C B A
POTI
Fuse Type: 2.5A - time-lag fuse - 250V - 5 x 20mm
Phasenabschnitt_V11
F1
2.5A T
Conrad Electronic
230V AC
LOAD
optional
Input:
AC Voltage
230 V~
Output:
max. 500W
Phase control by trailing edge PAD 500
Conrad order number: 17 50 00
Prescribed Use:
The phase control is suitable for:
- Ohmic loads such as light bulbs and e.g. R7s halogen rod lamps
- Capacitative loads such as dimmable electronic converters
These converters are preferably used in low-voltage halogen and LED technology.
Independently from power consumption, a maximum of two elect. transformers can be connected.
In connection with a potentiometer, the performance of these consumers can be controlled infinitely variable.
Not suitable for:
- Inductive load such as conventional transformer and electric motors of any kind.
Connection:
Maintenance and Cleaning:
Before cleaning, always power down the phase angle control (switch off circuit breaker).
A brush or extraction device can be used for cleaning.
Disposal:
Electric and electronic products must not be disposed of in the domestic waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.
Technical Data:
Soft start
Adjustment range: 0... 100%
Setting: By external potentiometer 47k linear (Conrad order number: 445583 - not included in the delivery)
Power: max. 500W (e.g. two electronic converters with 250W each)
Operating temperature range: 0 to 40°C
Storage temperature range: -20 to 80°C
Humidity: 15 - 95% RH, non-condensing
CE-compliant: No additional EMC measures required
Dimensions: approx. 116 x 42 x 29 mm
Weight: approx. 58g
These operating instructions are published by Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau
(www.conrad.com).
All rights, including translation, are reserved. Reproductions of any kind, e.g. photocopy, micro filming or recording in
electronic data processing systems require the written approval of the publisher. Reprints - in whole or part - are prohibited.
These operating instructions comply with the technical state of the art at the time of print.
We reserve the right to change the technical or physical specifications.
© Copyright 2010 by Conrad Electronic SE. *06/10-MA