Data Sheet

Table Of Contents
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k
0
values
Lead spacing 10 mm 15 mm 22.5 mm 27.5 mm
dV/dt in V/µs
550 400
200 150
k
0
in V
2
/µs
429 000 312 000
156 000 117 000
Impedance Z versus frequency f
(typical values)
B81130
X2 / 275 VAC
Not for new design