Datasheet

Specification and test method
Temperature Compensation Capacitors:
Operating Temperature Range
-30-+85
Operation humidity:
20 ~ 90% RH
Capacitance
Fulfilling the specified capacitance tolerance when measured at 25±2 with
1±0.1MHz and 3 Vrms max.
Test Voltage Working voltage ----- 50V
3 times of working voltage (50mA and under) for 1 to 5 second with no failure
Working voltage ----- 500V
2.5 times of working voltage (50mA and under) for 1 to 5 seconds with no failure
Insulation Resistance 10000Mmin at rated voltage ±3% within 60±5 sec of charging
Q Fulfills the specification stated on page 4 with the same condition test of
capacitance
High-Dielectric Constant Capacitors:
Operating Temperature Range
Y:-30-+85 Z:+10-+85
Operation humidity:
20 ~ 90% RH
Capacitance
Fulfilling the specified capacitance tolerance when measured at 25±2 with
1±0.1MHz and 3 Vrms max.
Test Voltage Working voltage ----- 50V-500V
2.5 times of working voltage (50mA and under) for 1 to 5 second with no failure
Working voltage -----1KV-2KV
2 times of working voltage (50mA and under) for 1 to 5 seconds with no failure
Insulation Resistance For capacitance<0.02uF: 10000Mmin at rated voltage ±3% within 60±5 sec of
charging
For 0.02uF< capacitance<0.1uF: 7500Mmin at rated voltage ±3% within 60±5
sec of charging
Q Fulfills the specification stated on page 4 with the same condition test of
capacitance
This data sheet is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved.
Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited. This data represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2015 by Conrad Electronic SE.