14. Rechargeable Battery and Solar Module
Test setup: Solar module, plug board, plug pins, resistor 100 Ω, red LED
The front of the unused solar module is protected with a lm. This must be
removed rst.
On the rear of the module there are two soldering connections with soldered-on
cables. The module supplies direct current. Thus, there are a red cable, the plus
pole, and a black cable, the minus pole, like in a battery. Push the cable through
the bores of the plug board (tension relief) and then connect the black and the red
cable to the plug board. It is recommended to plug the black connection into the
bottom rail and the red connection into the top rail.
The solar module may remain connected for the subsequent experiments.
a)