User`s manual
Master Audio
PA208A.Ver 1.1 Nov 09 16
HGC = +3dB
Far field
Fig.2. HF output level control
In a three-speaker array, the HFC on the top speaker is set at +3dB, the middle
speaker at 0 dB, and the bottom speaker at -3dB.
Fig.3. Example of applying the HFC
2.2. Connection Panel
a) BALANCED INPUT: XLR balanced signal connector.
1= Shield 2= Live 3= Return
b) LINK: XLR connector for parallel connection of various cabinets with the same
input signal.
1= Shield 2= Live 3= Return
c) AC MAINS: Mains supply via PowerCon
d) AC LINK: Power link for PowerCon connector to feed other units in parallel (up to
a maximum of 5 extra units).
e) 90Hz filter: High-pass filter at 90Hz for better coupling with subwoofer.
f) POWER ON: lights up with correct AC signal.