Specifications
Chapter 3: Configuring the ConnectPro Server 16
Parameter Description
Thefollowingisalistoftheloglevelsettings.Thenumbersinparenthesescan
beusedinplaceofthename.
CRITICAL(1)—Catastrophicerrorloggingonly
ERRORS(2)—Errorsonly
WARNING(3)—Errorsandwarnings
INFO(4)—Errors,warnings,informational
DEBUG(5)—Trouble-shootingmode
VERBOSE(6)—Alllogginginformation
Capture
ConnectProcancaptureproxycommunicationinformation.Usethefollowingformattocreate
acaptureentryintheConnectProconfiguration:
capture [on |off]
clear [on | off]
include [filter]
Thefollowingtablecontainsdetailedinformationaboutthecaptureentry.
Parameter Description
capture [on
| off]
Specifyeither on or off todeterminewhetherproxycommunication
dataiscaptured.
clear [on |
off]
Specifyeither on or off todeterminewhetherthedatacapturefileis
emptiedwhenConnectProstartsorrestarts.
include
[filter]
Specifyacomma-delimitedlistofClientIPaddressesthatwillhavetheir
datacaptured.
Usetheformat x.x.x.x/y tospecifyanentiresubnet.
Example: 10.0.0.0/8 indicatesaddresses10.0.0.0to10.255.255.255.
Donotusethe include parameterifyouwanttocapturethenetwork
trafficforalldevices.
Restart
UsethefollowingformattocreatearestartentryintheConnectProconfiguration:
restart [restart time]
Thefollowingtablecontainsdetailedinformationabouttherestartentry.