User`s manual

MeterHoldTime:
This parameter sets how long the OVERLOAD LED
will be lit after an overload is detected.
vMeterHoldFall:
This parameter sets how fast the meter should fall
back to normal metering after the OVERLOAD LED
has been invoked.
2 File
Pressing the File button will open the File menu that
allows you to load or save a preset.
Load
Byselecting“Load”,youcannavigatetoanyfolderon
thesystem,includingsharedfolders.Bydefault,you
will be directed to the default file location.
Save
Byselecting“Save”,youcansaveyourpresettoany
folder on the system that you have write access to,
includinganysharedfolder.Bydefault,presetsare
savedtothedefaultlocationfortheTCNearControl
Panel presets.
My Presets
This menu item provides easy access to your own
presets.Noticethatonlypresetslocatedinthedefault
filelocationsfortheTCNearControlPanelwillbe
visible in the drop down menu.
3 A/B
WiththeA/Bcomparefunctionyoucaneasily
compare different parameter settings when working
with the plug-in.
Whenyoustartworkingonapreset,neitherAorBis
highlighted.
This state indicates that the settings in both memory
locationsAandBareidentical–sothereisactually
nothing to compare.
As soon as you touch one of the parameters, the
memorylocation“A”willbeactive–andhighlighted.
All parameter changes will be applied to memory
location“A”.Ifyouswitchtomemorylocation“B”,
you go back to the starting point, and all further
changeswillnowbeappliedtomemorylocation“B”.
EverytimeyoupresstheA/Bbutton,youwilltoggle
between these two memory locations.
TheA/Bmemorylocationsaretemporarysettings
only! Saving a preset will save the currently
selected memory location only. The setting of the
other (hidden) memory location will not be saved!
4 Reset
Click the “Reset” button to clear the memory slots
A/Bandreturntotheoriginallyrecalledpreset.
5 Output Meter
This is the output meter for the M40 Studio
Reverb (see also descriptions of the parameters
MeterFallBack,MeterHoldTimeandMeterHoldFallin
the“1–Inputmeter”section).
6 Preset Name
This is the name of the currently recalled preset.
Scroll through presets using the up/down arrows on
the right side of the name display.
7 Algorithm
This is the currently selected reverb algorithm. The
available options are Hall, Room and Plate.
M40 STUDIO REVERB M40 STUDIO REVERB
1716
1 Input Meter
This is the input meter for the M40 Studio
Reverb.
Click on the meter using the left mouse button
to select various meter options.
MeterFallback:
This parameter sets how fast the meter
shouldfallbackafterpeaks.ThemoredBs
per second, the faster the meter falls back.
The M40 Studio Reverb is an easy-to-use reverb for both monitoring and mixing. The reverb exist in two variations:
A-asastandardVST/AUplug-inthatcanbeusedjustasanyotherVST/AUplug-infromyourDAWhostapplication.Notice
that the M40 Studio Reverb is copy protected by the Desktop Konnekt 6. If the Desktop Konnekt 6 is not attached to the
computer, the plug-in will be disabled.
B-asapartoftheTCNearControlPanelwhereitcanbeusedasanexcellentcuereverbfortherecordingartist.Inthis
situationitisworthnoticingthattheTCNearControlPanelMUSTbeopenforthereverbtorun.