User`s manual

MeterHoldTime:
This parameter sets how long the OVERLOAD LED
will be lit after an overload is detected.
vMeterHoldFall:
This parameter sets how fast the meter should fall
back to normal metering after the OVERLOAD LED
has been invoked.
2 File
Pressing the File button will open the File menu that
allows you to load or save a preset.
Load
Byselecting“Load”,youcannavigatetoanyfolderon
thesystem,includingsharedfolders.Bydefault,you
will be directed to the default file location.
Save
Byselecting“Save”,youcansaveyourpresettoany
folder on the system that you have write access to,
includinganysharedfolder.Bydefault,presetsare
savedtothedefaultlocationfortheTCNearControl
Panel presets.
My Presets
This menu item provides easy access to your own
presets.Noticethatonlypresetslocatedinthedefault
filelocationsfortheTCNearControlPanelwillbe
visible in the drop down menu.
3 A/B
WiththeA/Bcomparefunctionyoucaneasily
compare different parameter settings when working
with the plug-in.
Whenyoustartworkingonapreset,neitherAorBis
highlighted.
This state indicates that the settings in both memory
locationsAandBareidentical–sothereisactually
nothing to compare.
As soon as you touch one of the parameters, the
memorylocation“A”willbeactive–andhighlighted.
All parameter changes will be applied to memory
location“A”.Ifyouswitchtomemorylocation“B”,
you go back to the starting point, and all further
changeswillnowbeappliedtomemorylocation“B”.
EverytimeyoupresstheA/Bbutton,youwilltoggle
between these two memory locations.
TheA/Bmemorylocationsaretemporarysettings
only! Saving a preset will save the currently
selected memory location only. The setting of the
other (hidden) memory location will not be saved!
4 Reset
Click the “Reset” button to clear the memory slots
A/Bandreturntotheoriginallyrecalledpreset.
5 Output Meter
This is the output meter for the M40 Studio
Reverb (see also descriptions of the parameters
MeterFallBack,MeterHoldTimeandMeterHoldFallin
the“1–Inputmeter”section).
6 Preset Name
This is the name of the currently recalled preset.
Scroll through presets using the up/down arrows on
the right side of the name display.
7 Algorithm
This is the currently selected reverb algorithm. The
available options are Hall, Room and Plate.
M40 STUDIO REVERB M40 STUDIO REVERB
1716
1 Input Meter
This is the input meter for the M40 Studio
Reverb.
Click on the meter using the left mouse button
to select various meter options.
MeterFallback:
This parameter sets how fast the meter
shouldfallbackafterpeaks.ThemoredBs
per second, the faster the meter falls back.
The M40 Studio Reverb is an easy-to-use reverb for both monitoring and mixing. The reverb exist in two variations:
A-asastandardVST/AUplug-inthatcanbeusedjustasanyotherVST/AUplug-infromyourDAWhostapplication.Notice
that the M40 Studio Reverb is copy protected by the Desktop Konnekt 6. If the Desktop Konnekt 6 is not attached to the
computer, the plug-in will be disabled.
B-asapartoftheTCNearControlPanelwhereitcanbeusedasanexcellentcuereverbfortherecordingartist.Inthis
situationitisworthnoticingthattheTCNearControlPanelMUSTbeopenforthereverbtorun.