Users Manual

Page | 18
WARNING
The approaches to ground and neutral connections have numerous variables. The
connection method can vary based on utility and authority having jurisdiction
requirements, accessory components chosen, meter socket type, and overall system
configuration.
Coordinate with your utility and authority having jurisdiction to establish acceptable
methods in cases where methods recommended below cannot be employed.
Due to the wide variety of meter socket styles and locations where a neutral could be
terminated, a given site may require a longer neutral than the one provided in the
box, or a different type of wire. It is the responsibility of the installer to make certain
the neutral is terminated in an approved manner.
Possible options for connecting the neutral pigtail to the meter socket:
If a grounded terminal is available, attach the end of the neutral wire pigtail lead. This
option is depicted in FIGURE 10 below. Torque to manufacturers specified value.
FIGURE 10