Users Manual
ME910C1 HW User Guide
1VV0301351 Rev.13 Page 90 of 106 2020-06-30
Tsmax to TL
– Ramp-up Rate
3°C/second max
Time maintained above:
– Temperature (TL)
– Time (tL)
217°C
60-150 seconds
Peak Temperature (Tp)
245 +0/-5°C
Time within 5°C of actual Peak
Temperature (tp)
10-30 seconds
Ramp-down Rate
6°C/second max.
Time 25°C to Peak Temperature
8 minutes max.
NOTE:
All temperatures refer to topside of the package, measured on the
package body surface
WARNING:
THE ME910C1 MODULE WITHSTANDS ONE REFLOW PROCESS
ONLY.