Figure 15 Door Lock/Unlock using a Remote Starter with Trigger input
Figure 16 Direct Connection to Negative Door Lock System/Trigger
Figure 17 Direct Connection to Positive Door Lock Triggers
11.8. White Wire / ARM TRIGGER WIRE (Pin12) input (+ve):
This wire (white) is the Arm Monitor wire. Once the Anywhere Device detects an armed pulse, it
puts itself in the armed state. Once armed it responds to intrusion detection of
Doors/Trunk/Hood/Ignition/Alarm siren. The arm command is also enabled anytime you send the lock
command via the phone interface.
In essence this input synchronizes the Anywhere unit with your factory alarm system, incase you
disarm/arm the car with your local keyfob unit when you are in range of the vehicle.
Connection:
The pin-12 (white) terminal should be connected to the factory arm output terminal or the arm output of
an alarm system. Through this terminal, the device monitors the arm state of the vehicle. This terminal
should not be left open.
Hint:
The factory arm output wire should give a positive (+ve) pulse when the alarm/security unit is armed. If it
gives a negative pulse, use relays/diodes to convert the output to a positive pulse.
11.9. Gray/Ash Wire / DISARM TRIGGER WIRE (Pin10) input (+ve):
This wire (gray/ash) is the Disarm Monitor wire. Once the Anywhere Device detects a disarmed pulse, it
puts itself in the disarmed state. Once disarmed, it stops responding to intrusion detection of