Operating instructions

5 / 16
EN-TraceTekTTTS12-IM-H8085601/15
THERMAL BUILDING &
INDUSTRIAL HEAT TRACING SOLUTIONS
3. Disconnect the connector on the back of the buzzer
REMOVING THE BACK PLANE ASSEMBLY AND WIRE HARNESS:
1. The back plane assembly and wire harness are designed to be removed as a single unit with a minimum of disruption to the internal
wiring.
2. At the rear of the TS12 touch screen, disconnect:
a. 24VDC Power Connection terminal block (may be secured by small screws)
b. RS485/RS422 Connector (may be secured by small screws or finger tighteners)
c. RS232 Connector (may be secured by small screws or finger tighteners)
4. Unsnap (open) two wire harness holders on the door and two wire harness holders on the left side of the enclosure tub. Gently
remove the wire harness from the holders.
CABLE GLAND AND CONDUIT ENTRIES
The primary cable entry surface is the bottom edge of the TT-TS12-Panel enclosure. Alternate entry points may be appropriate for some
installations. It is the responsibility of the installer to note internal clearance and choose standard entry points such that the wire and
cable routing do not interfere with the internal components.
Note: Remove the back plane assembly and wire harness prior to drilling or punching holes for cable glands or conduit entries
because of the risk of damage to the components or contamination due to metal filings.
3 2c 2b 2a
Door wire harness holders Enclosure wire harness holders