Instruction manual
Depress   to navigate to Preset. With Preset highlighted depress   to make constant 
ctive for change. The sign preceding the base a
number is highlighted. Use 
 or   to change 
sign. Depress 
the 
 to navigate the cursor to the first 
digit to be changed for this example. Use 
 or   
to increment or decrement the number as required. Use 
 for each additional digit to 
hange. Change the exponent sign in the same manner as described for the sign preceding 
e base number. 
epress Next, 
c
th
D
, to navigate to the Input B Setup page. When changes are complete, 
depress 
. If no mo e changes are to be made on this pager  the user may depress Prev, 
, multiple times to exit and save changes as described in section 4.1.2. 
onfigure Input B. 
4.2 and TT30 Only), Relay Output 
1&2 / Digital Output Setup (Tachometer and Counter Mode) 
; Relay 1 and 2 are based on 
 and power switching but do not 
nductors. Each mechanical relay has a set of 
normally open and normally closed contacts. Digital 1 & 2 are semi-
conductor based outputs that reduce reaction time, but switch lower power 
levels and have only a true normally open condition. Just as with the 
mechanical relays, there is no polarity associated with these outputs. The 
switched outputs react when a particular setpoint is reached. A setpoint is a 
If Direction mode is active, only Input A will be active and there will not 
be a choice to c
.4.  Digital Output 1&2 (TP30 
The tachometer has four switched outputs
mechanical relays that provide high isolation
react as quickly as semi-co
53