Operating instructions
SEA M300USERSGUIDE
SETUP
114
For a system frequency of 100 hz, buffer frequencies of 20 hz and 25 hz are possible.
For a system frequency of 160 hz, buffer frequencies of 20 hz is possible, but 25 hz would not be
possible. For system frequency of 160 hz, the next possible frequency after 20 hz is 32 hz.
State
Buffer state to turn on or off a particular buffer.
Record
Buffer record state to turn on or off recording of a particular buffer. If the state is turned off these
buffers will not be recorded by the M300 record manager (m300r).
Broadcast
Buffer broadcast state to turn on or off broadcasting of a particular buffer. If the state is turned off
these buffers will not be broadcast by the M300 broadcast manager (m300b).
Home
Moves the selected item to the top of the list.
End
Moves the selected item to the bottom of the list.
Up
Moves the selected item up the list by one.
Down
Moves the selected item down the list by one.
Done
This will close the buffer setup window.
WARNING:Anychangesmadewillbeaccepted.Ifyoudon’twantthechangestotakeeffect,don’tsavethe
M300project.
If you are happy with the changes to the board setup, you can exit and save the project or just save
the project (from M300 project menu).
BufferTree
The buffer tree is made up of the project name at the top.
From the name the tree splits into all the buffers in the project.
Each buffer line displays important information about the buffer. It starts with the buffer number,
followed by the type of the buffer (type of the data), (S) for synchronous buffer or (A) for