Operating instructions

SEA M300USERSGUIDE
SETUP

112
BUFFERSETUP
1. In the Setup menu, select Buffer. (Shortcut: Alt + S, U)
The buffer setup dialog allows the user to control almost all the functionality of the M300 related to
the M300 buffers. The buffer numbers get assigned automatically when adding the acquisition
events. If necessary or desired they can be changed manually with the editor for the buf.300 project
file.
Here are a few important items to consider when it comes to the M300 buffer management.
The order of the buffers specified on the tree is the order in which they will be used for acquisition.
The order is important some times critical.
Buffer 0, sync 1 hz buffer must always be at top.
Other sync buffers faster than 1 hz, must follow the sync 1 hz buffer.
Valid buffer numbers are from 1 to 250.
Buffer 251 is reserved for command, buffer 252 is reserved for error, buffer 253 is reserved for
secondary acquisition. These must be last in the project.