15.3.2 Xtreme/104 Plus and /PCI-104 ID Selection Using the Jumper Block
If your Xtreme/104-Plus or Xtreme/PCI-104 card is equipped with a jumper block for ID
selection, set your board’s location by changing jumper positions. Figure 7 depicts the jumper
settings required for each ID.
The jumpers remain unpopulated for an ID of zero. Populate the left jumper for an ID of one, the
right jumper for an ID of two or populate both for an ID of three.
Figure 10: Jumper Settings for ID Selection
15.3.3 XIG 12 Port Opto Selection Using the Miniature Rotary Switch (RevC)
The XIG 12 Port opto family is equipped with a rotary switch, turn the knob on the switch so
that the arrow points at the ID you would like to use. Use the following settings to set your
adapter’s location (or PCI ID) within the stack:
Module Slot
Switch Position
1
0
2
1
3
2
4
3
Figure 11: Rotary Switch ID Selection