User manual

3-42 Chapter 3: Software Installation - Windows NT
Echo User's Manual, ver. 0.00
14.19. Choose EDIT, then ADD VALUE, and enter in the
following values EXACTLY as below.
Value Name: InterruptStatus
Data Type: REG_DWORD
Value: 2C0
(Highlight Hex format Check Box)
Note:
1. For our example of Base I/O address 280, the
Echo status port is at I/O address 2C0.
2. The Value is the address of the status port
corresponding to I/O address range set on the
Echo adapter. All Echo ports on a single
board will have the same status port address,
so each key Serial10000, Serial10001 up to
Serial1000n will have the same value.
Once again choose EDIT, then ADD VALUE, and enter
in the following values EXACTLY as below.
Value name: PortIndex
Data Type: REG_DWORD
Value: 1
Note:
Each key Serial10000, Serial10001 up to Serial1000n
will get a unique entry for its Value. You will enter 1
for Echo port one, 2 for port two, etc.
14.20. Exit the Registry Editor and the system
automatically saves the new values.
15. You can now reboot your system and your Windows NT
applications can access all the Echo serial ports.