Technical data

Safety Integrated Functions in
SINAMICS Drive Systems
6.2 Safety Integrated functions in SINAMICS S120 drive systems
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
185
Controlling Safety Integrated functions
Safety Integrated functions can be controlled as follows:
Via terminals
Via a PROFIsafe message frame using PROFIBUS
Via the terminal module TM54F - for the extended functions
Controls can be selected simultaneously via terminals and TM54F or terminals and
PROFIsafe.
Hardware components that support the extended functions
Control Unit CU310 with order no.: 6SL3040-0LA00-0AA1/6SL3040-0LA01-0AA1
Control Unit CU320 with order no.: 6SL3040-...-0AA1 and version C
Control Unit CU320-2
CX32 (without restrictions)
Motor Modules Booksize with order no.: ...3 or higher
Motor Modules Booksize Compact
Power Modules Blocksize
Control Unit adapter CUA31 with order no.: 6SL3040-0PA00-0AA1
Control Unit adapter CUA32 with order no.: 6SL3040-0PA01-0AA0
Sensor Module SMC20, SME20/25/120/125
Requirement for Extended functions
License for Safety Integrated extended functions
In contrast to the basic function, an appropriate license is required to use the
Safety Integrated extended functions. An insufficient license is indicated via the following
alarm and LED:
A13000 -- > License not sufficient
LED READY -- > Flashes green/red at 0.5 Hz
Control via PROFIsafe or TM54F
A safe actual value acquisition
An activated speed controller in the drive