Technical data

Basic functions
4.3 Triggering of the integrated outputs of the CU 320 Control Unit
Connection of the SINAMICS S120 to the Technology CPU
126 Product Information, 09/2011, A5E00480378-04
Creating the S7 user program
Use the Technology Object Manager (TOM) to create a technology data block (TO-DB),
which is assigned to the homing output cam technology object. The technology data block
(TO-DB) allows the functions on the associated technology object to be executed using the
provided FBs.
For the output cam, use the FB 430 MC_CamSwitch function block in your S7 program.