Hardware configuration
A typical application example is an encoder without zero mark evaluation. An external zero
mark (Bero) is used in place of the encoder zero mark. To ensure short response times, it is
read indirectly via the digital inputs of the CU320. The same signal is also evaluated via an
integrated input on the Technology CPU.
7HFKQRORJ\&38
PROFIBUS connection
LQWHJUDWHG
LQSXWRXWSXWV
RI7&38
'LJLWDO
LQSXWRXWSXWV
&8
'ULYH&/L4FRQQHFWLRQ
6,1$0,&66
Reference cam
0RWRUZLWKPRWRUHQFRGHU
M
CU320
X122
X132
ALM
BLM
SLM
Single
Motor
Module
Double
Motor
Module
X10 0
X10 1
X20 0
X201
X202
X20 0
X201
X20 2
X20 3
Allocating the zero mark substitute signal to the digital input of the SINAMICS and inverting the
selected digital inputs of the SINAMICS
Assign the digital input of SINAMICS as a zero mark substitute signal as described in
Section 4.2.3 Example of active homing with external zero mark only.
If necessary, invert the input that was used to detect the zero mark substitute signal as
described in section 4.2.3 Example of active homing with external zero mark only.