3.6.3 Time-based cam
Switching response
The switching response of time-based cams is determined by the ON and OFF
positions. An additional effective direction may be defined.
Switching action
based on
The time-based cam is
switched on
The time-based cam is switched
off
Switch-on position
at the ON position
ON duration when the configured interval has
expired
Force direction at the ON position, if the motion
direction corresponds with the
effective direction
when the configured interval has
expired
Note
Time-based cams can not be retriggered.
Inverted output
To invert the output, the time-based cam is active, and is deactivated at the
switching position for the duration of the specified time.