Technical data

Appendix
CPU 317T: Technology Functions
A-62 A5E00251798-03
Name
(Expert list in S7T Config)
Values Description S7 Int.
technolog
y
EFFECTIVE Last programmed setting 3 45
AXIS_STOPPED_AT_ POSITION Stop before SyncOff position 73 15
BEGIN_TO_STOP_WHEN_
POSITION_ REACHED
Stop at SyncOff position 74 18
STOP_SYMMETRIC_WITH_
POSITION
Stop symmetrically to SyncOff position 75 137
EnumSyncPositionReference USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed setting 3 45
BE_SYNCHRONOUS_AT_
POSITION
Synchronize before sync position 76 19
SYNCHRONIZE_
SYMMETRIC
Synchronize symmetrically to sync position 77 143
SYNCHRONIZE_WHEN_
POSITION_ REACHED
Synchronize from sync position 78 144
EnumSyncProfileReference USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed setting 3 45
RELATE_SYNC_PROFILE_
TO_ LEADING_VALUE
Master axisspecific synchronization profile 79 113
RELATE_SYNC_PROFILE_
TO_TIME
Timerelated synchronization profile 80 114
EnumToActivationMode SetConfigData ACTIVATE_CHANGED_
CONFIG_DATA
Enable configuration data immediately 81 291
COLLECT_CHANGED_
CONFIG_DATA
Collect changed configuration data, do not enable 82 292
EnumYesNo NO Enable: No 0 91
YES Enable: Yes 1 173
RESERVE_EnumOutput CamType TYPE_SWITCH Switching cams 62 2
TYPE_REVERSE Reversing cam 63 3