Technical data
Appendix
CPU 317T: Technology Functions
A5E00251798-03
A-61
Name
(Expert list in S7T Config)
Values Description S7 Int.
technolog
y
VALID Values are valid 111 206
EnumSyncModeCamming USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed setting 3 45
IMMEDIATELY Effective immediately 8 60
AT_THE_END_OF_
CAM_CYCLE
Transition at the end of the active cam 68 14
NEXT_WITH_ REFERENCE At the next master axis position/not available 69 90
ON_MASTER_AND_SLAVE_
POSITION
Specification of the sync position of the master axis and slave axis 70 99
ON_MASTER_POSITION Default synchronization position of master axis 71 100
EnumSyncModeGearing USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed setting 3 45
IMMEDIATELY Effective immediately 8 60
NEXT_WITH_ REFERENCE At the next master axis position/not available 69 90
ON_MASTER_AND_
SLAVE_POSITION
Specification of the sync position of the master axis and slave axis 70 99
ON_MASTER_POSITION Default synchronization position of master axis 71 100
ON_SLAVE_POSITION Synchronization before synchronization position 72 101
EnumSyncOffMode Camming USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed setting 3 45
IMMEDIATELY Effective immediately 8 60
AT_THE_END_OF_
CAM_CYCLE
End of cam cycle 68 14
ON_MASTER_POSITION At position of master axis 71 100
ON_SLAVE_POSITION at the position of the slave axis 72 101
EnumSyncOffModeGearing USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed setting 3 45
IMMEDIATELY Effective immediately 8 60
ON_MASTER_POSITION Default SyncOff position of the master axis 71 100
ON_SLAVE_POSITION Default SyncOff position of the slave axis 72 101
EnumSyncOffPositionReference USER_DEFAULT User default / default 2 149