Technical data

Appendix
CPU 317T: Technology Functions
A-60 A5E00251798-03
Name
(Expert list in S7T Config)
Values Description S7 Int.
technolog
y
EnumMeasuredEdge USER_DEFAULT User default / default 2 149
FALLING_EDGE Negative edge (hi to lo) 53 86
RISING_EDGE Positive edge (lo to hi) 54 117
BOTH_EDGES Measurement triggered at both edges 55 224
BOTH_EDGES_FIRST_
RISING
Measurement triggered at both edges, starting at the positive edge
(lo to hi)
56 225
BOTH_EDGES_FIRST_
FALLING
Measurement triggered at both edges, starting at the negative edge
(hi to lo)
57 226
EnumMeasuringRangeMode USER_DEFAULT User default / default 2 149
WITHOUT_SPECIFIC_ AREA Measurement without specified area 58 168
WITH_SPECIFIC_AREA Measurement in the specified area 59 170
EnumMountSwitch END_MOUNTED_SWITCH limit switch outside the permissible traversing range is always active
103 0
FLEXIBLE_MOUNTED_ SWITCH Limit switch may be passed 104 1
EnumOutputCamType TYPE_WAY Position-based cam 60 0
TYPE_TIME Time-based cam 61 1
EnumProfile USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed speed profile 3 45
PARABOLIC Parabolic speed profile/not available 64 103
SINUSOIDAL Sinusoidal speed profile / not available 65 122
SMOOTH Smooth acceleration curve 66 124
TRAPEZOIDAL Trapezoidal speed profile 67 146
EnumRecognitionMode DO_NOT_CLAMP no detection 105 0
CLAMP_BY_FOLLOWING_ ERROR_
DEVIATION
when value of follow-up error is exceeded 106 1
CLAMP_WHEN_TORQUE_ LIMIT_ REACHED when torque limit is reached /not available (or to be verified) 107 2
EnumSlaveMode USER_DEFAULT User default / default 2 149
EFFECTIVE Last programmed slave mode 3 45
ABSOLUTE Reference to slave is absolute 6 1
RELATIVE Reference to slave is relative 7 115
EnumSensorState NOT_VALID Invalid 109 204
WAIT_FOR_VALID Waiting for validity 110 205