Technical data
Technology objects
CPU 317T: Technology Functions
A5E00251798-03
3-35
3.6.1 Position-based cam
Note
The definition of the ON range applies to modulo axes with cyclic motion range.
ON range
The ON range of position-based cams is defined by the distance between the On
and OFF positions in positive counting direction.
The ON position value is lower than that of the OFF position:
The ON range is out of range if it exceeds the OFF range.
The ON position value is higher than that of the OFF position: