Technology parameters - External encoders
No. Name
(standard in S7T Config)
Name
(Expert list in S7T Config)
Data type Index min. max. Access Active Description
1100 Mechanical spindle setting.
Spindle pitch per axis
revolution
LeadScrew.pitchVal REAL - 0.0 1E+12 R, W Restart Spindle pitch per axis revolution
1110 Synchronization extrapolator.
Extrapolation time
TypeOfAxis.Extrapolation.
ExtrapolationTime
REAL - 0.0 1E+12 R, W Immediately Extrapolation time for master axis
1111 Synchronism.Extrapolator.Filte
r. Mode
TypeOfAxis.Extrapolation.
Filter.Mode
DINT
EnumAxisFilter
Mode
- - - R, W Restart Selection criterion for actual value
smoothing
1112 Synchronism.Extrapolator.Filte
r. Activation
TypeOfAxis.Extrapolation.
Filter. enable
DINT EnumYesNo
- - - R, W Immediately Activation status
1113 Synchronism.Extrapolator.Filte
r. Time constant
TypeOfAxis.Extrapolation.
Filter. timeConstant
REAL - 0.0 1E+12 R, W Immediately Time constant for PT1 smoothing
1114 Synchronization extrapolator.
Tolerance range.Activation
TypeOfAxis.Extrapolation.
ToleranceRange.Enable
DINT EnumYesNo
- - - R, W Immediately Enable tolerance range
1115 Synchronization extrapolator.
Tolerance range. Tolerance
window
TypeOfAxis.Extrapolation.
ToleranceRange.Value
REAL - -1E+12 1E+12 R, W Immediately Tolerance window
1201 Mechanical Modulo. Activation
Modulo. state DINT EnumActive
Inactive
- - - R, W Restart Activation of modulo settings
1202 Mechanical Modulo. Length Modulo. length REAL - -1E+12 1E+12 R, W Restart Modulo length
1203 Mechanical Modulo. Start
value
Modulo. startValue REAL - -1E+12 1E+12 R, W Restart Modulo start value
1221 Monitoring Speed Activation TypeOfAxis.
ActualVelocityMonitoring.
enable
DINT EnumYesNo
- - - R, W Immediately Enable actual speed monitoring
1222 Monitoring Speed Maximum
value
TypeOfAxis.
ActualVelocityMonitoring.
maximum
REAL - 0.0 1E+12 R, W Immediately Maximum permitted actual speed
1331 Configuration Actual value
smoothing Activation
TypeOfAxis. SmoothingFilter.
enable
DINT EnumYesNo
- - - R, W Immediately Enable filter functionality
1332 Configuration Actual value
smoothing Mode
TypeOfAxis. SmoothingFilter.
mode
DINT Enum
AxisFilterMode
- - - R, W Restart Method for calculating actual value
smoothing
1333 Configuration Actual value
smoothing Time constant
TypeOfAxis. SmoothingFilter.
timeConstant
REAL - 0.0 1E+12 R, W Immediately Time constant for PT1 smoothing
1351 Monitoring Standstill signal
Message delay time
TypeOfAxis. StandStillSignal.
delayTimeToActivate