Technical data

Appendix
CPU 317T: Technology Functions
A-50 A5E00251798-03
No. Name
(standard in S7T Config)
Name
(Expert list in S7T Config)
Data type Index min. max. Access
Active D P V Description
4334 Synchronous operation
Synchronization
Synchronization reference
userdefault.syncProfile.
syncPositionReference
DINT Enum
SyncPosition
Reference
1-2 - - R, W Immediately X
Position of the synchronization
profile to the synchronizing
position
4335 Synchronous operation
Synchronization Profile
reference
userdefault.syncprofile.
syncprofilereference
DINT Enum
SyncProfile
Reference
1-2 - - R, W Immediately X Reference variable of
synchronization profile
4400 Actual values.limits. SW limit
switch.Status SW limit switch
minus
swlimitstate.swlimitswitchminus
DINT
EnumLimit
ExceededOk
- - - R - - X X Software limit switch minus
4401 Actual values.limits. SW limit
switch.Status SW limit switch
plus
swlimitstate.swlimitswitchplus DINT
EnumLimit
ExceededOk
- - - R - - X X Software limit switch plus
4410 Actual values.limits. Hardware
limit switches Status HW limit
switch minus
sensormonitoring.
hwlimitswitchminus
DINT
EnumLimit
ExceededOk
- - - R - X X X Hardware limit switch minus
4411 Actual values.limits. Hardware
limit switches Status HW limit
switch plus
sensormonitoring.
hwlimitswitchplus
DINT
EnumLimit
ExceededOk
- - - R - X X X Hardware limit switch plus
4412 Actual values.Measuring
system.Active encoder
sensormonitoring.actualsensor DINT - 1 16 R - X X X
Number of active
encoder/sensor
4500 Setpoints.Drive.Control word.
Control word
driveData.stw.STW CDWORD - - - R, W - X X X
Control word 1 and 2
4501 Actual values.Drive. Status
word.Status word
driveData.ztw.ZTW DWORD - - - R - X X X
Status word 1 and 2