Technical data
Appendix
CPU 317T: Technology Functions
A-36 A5E00251798-03
No. Name
(standard in S7T Config)
Name
(Expert list in S7T Config)
Data type Index min. max. Access
Active D P V Description
1274 Monitoring Synchronous
operation monitoring Activation
of setpoint monitoring
TypeOfAxis.
GearingPosTolerance.
enableCommandValue
DINT Enum
Gearing
PosTolerance
Command
Value
- - - R, W Immediately X Setpoint tolerance monitoring
1275 Monitoring Synchronous
operation monitoring Message
to master
TypeOfAxis.
GearingPosTolerance.
enableErrorReporting
DINT Enum
ErrorReporting
- - - R, W Immediately X Message of tolerance
monitoring
1281 Limits Position and Speed
Hardware limit switches
Activation
TypeOfAxis. HWEndPos.
Enable
DINT
EnumYesNo
- - - R, W Restart X X X Activation of limit switches
1284 Position and speed limits
Hardware limit switch.Modus
TypeOfAxis.HWEndPos.
Mode
DINT
EnumMount
Switch
- - R, W Restart X X X Position of the HW limit
switch relative to the axis
traversing range
1291 Limits Dynamic response
Acceleration Activation of
monitoring functions
TypeOfAxis.MaxAcceleration.
enableSetPointMonitoring
EnumYesNo - - - R, W Restart X X X Enable manipulated variable
monitoring