Technical data

Download, testing and diagnostics
CPU 317T: Technology Functions
8-28 A5E00251798-03
Function generator parameter settings
Field Description
Name
SINAMICS Trace:
Parameters
Parameter name of the variable for which the function generator returns the
value.
You can enter this directly, or select it in the"Function generator signal
selection" view. To do so, click "Signal selection" at the end of the field. This
view shows all system variables available for the technology objects.
Syntax for entering the signal name:
<name of drive object>.<parameter number>
You must have created at least one technology object in the project.
You can also output the signals of both function generators to one system
variable. The signals are then superimposed (not with SINAMICS Trace).
FctGen Cycle
(not SINAMICS Trace)
The selected system variable is updated with the function generator signal in
the function generator cycle. Specify the cycle as a multiple of the position
controller cycle.
Note:
To generate a precise reconstruction of the trace shape selected under "Signal
type" by means of the function generator, the function generator cycle must be
significantly shorter that the signal period.
Signal type Here you select cyclic or acyclic signals with a different trace profile, which you
want to generate by means of the function generator.
Enter the required signal parameters. Which parameters are available
depends on the selected signal type.
Individual trace parameters displayed in red print indicate that the values you
have entered are not valid.