Technical data

Download, testing and diagnostics
CPU 317T: Technology Functions
8-22 A5E00251798-03
Field / button Description
Table "No.:" Shows the channel number.
The "Enabled:" check box
Set this check box to record the channel. You can enable all 8 channels. (Only
4 channels can be enabled in SINAMICS Trace.)
"Signal:" Name of the variable that is to be recorded.
You can enter this directly, or select it in the"Signal Selection" view. To do so,
click "
..." at the end of the field in the "Signal" column. This view shows all
available variables (system variables, I/O variables, global device variables,
unit variables, local variables of the programs in the runtime system, etc.).
Syntax for entering the signal name:
<name of drive object>.<parameter name / number>
Comment:
You can give the channel a name of your choice. If you do not enter a new
name, the program automatically uses the standard name of the parameter.
color :
Set the color of the recorded curve
SINAMICS Trace: Further fields
Field / button Description
Device cycle Cycle clock of the drive in ms
This cycle is the minimum trace clock in which the signal can be recorded.
Factor Enter a number n as the reduction factor if you want to start logging at each n-th
cycle.
Trace cycle Trace cycle in ms.
This is the cycle used to record every value of the signal. The trace cycle is a
multiple of the device cycle.