Technical data

Technology DBs
CPU 317T: Technology Functions
A5E00251798-03
7-57
ErrorID
Error message Possible causes To correct or avoid errors Interrupts in
S7T Config*
8045 Illegal command with
current status
A command of higher
priority is busy (e.g.
MC_Stop).
The technology object is
disabled or not ready.
Received measurement
command when homing
Acknowledge all queued errors of
the technology object.
Wait for the initialization of the
technology object (after restart).
Enable the technology object.
Disable MC_Stop.
Do not start any measuring
commands during homing.
30006, 30009
8047 Can not acknowledge
this error
It is not possible to reset the
error with FB MC_Reset.
Examples:
An axis has been brought
to standstill, and the error
causing this can not be
acknowledged.
Further errors occur in the
acknowledgment or restart
phase.
Eliminate all causes of error and
retry to acknowledge. Please note
that you must acknowledge
particular errors by cycling power.
30007
8048 Unable to restart The object is busy or a queued
error prevents restart.
Eliminate and acknowledge all
queued errors and disable the
object.
20012
8049 Illegal object
combination
Faulty combination of
technology objects. Examples:
Axis_2 was set as leading
synchronization axis for
Axis_1, while Axis_1 is set
as leading axis for Axis_2.
All synchronized drives are
processed at different run
levels.
Set a definite leading /
following axis combination.
Assign the leading / following
axes to the same run level
(usually the interpolator
cycle).
20007
804A The required object
interconnection is
missing
No allowances have been
made in the application
program for relevant
combinations of leading /
following axes and cam disks.
Set the required leading axes and
cam disks in the "Configuration"
section of the synchronization
object of the following axis.
30008
8051 Read / write access
denied.
An attem
pt was made to delete
a cam, or to adjust it while it
was in use.
Necessary procedure:
Terminate synchronous operation
of the cam, then edit it.
40001, 40002
8060 Error when adding a
cam segment
The new cam segment is
faulty, e.g. its start and end
points are identical.
Check the values defining the new
cam segment.
40004
8061
Cam position out of the
definition range/
range of values
The master/following axes
defined at "MC_GetCamPoint"
do not exist in the definition
range/
range of values of the cam
disk.
Enter a valid position at
"MC_GetCamPoint".
40005, 40006
8062 Access to an
interpolated cam
denied
An illegal command was
output to an already
interpolated cam.
Example:
MC_CamSectorAdd
You can not adjust a cam while it
is in use. Before you do so, delete
it with MC_CamClear.
40007
* Interrupts in S7T Config, which may be associated with the indicated error.