Technical data
Technology DBs
CPU 317T: Technology Functions
7-48 A5E00251798-03
ErrorID
Error message Possible causes To correct or avoid errors Interrupts in
S7T Config*
8049 Illegal object
combination
Faulty combination of
technology objects. Examples:
• Axis_2 was set as leading
synchronization axis for
Axis_1, and Axis_1 was
set as leading axis for
Axis_2.
• All synchronized drives are
processed at different run
levels.
• Set a definite leading /
following axis combination.
• Assign the leading / following
axes to the same run level
(usually the interpolator
cycle).
20007
804A The required object
interconnection is
missing
No allowances have been
made in the application
program for relevant
combinations of leading /
following axes and cam disks.
Set the required leading axes and
cam disks in the "Configuration"
section of the synchronization
object of the following axis.
30008
804B Limit switch actuated;
illegal command
A hardware
limit switch is actuated.
Permitted are only motion
commands in direction of the
operating range.
Check the mechanical installation
and the wiring.
Correct any programming errors
or use the software limit switches.
50009
8091 Error in pressure
control
Reserved error 50014, 50111
8092 Error in force limit
monitoring
Reserved error 50109, 50110
* Interrupts in S7T Config, which may be associated with the indicated error.