Technical data
Technology DBs
CPU 317T: Technology Functions
A5E00251798-03
7-47
ErrorID
Error message Possible causes To correct or avoid errors Interrupts in
S7T Config*
8032 Can not shift the
coordinate system
The programmed shift of the
coordinate system
(set or correct the actual
position value) leads to a
violation of the internal
traversing range. The
coordinate system is not
shifted.
Check the programmed shift of
the coordinate system.
30014
8033 Zero mark monitoring
triggered
Wrong number of increments
between two zero marks of the
encoder.
Check the wiring and the set
encoder resolution.
50006
8040 The axis / external
encoder is not
enabled, or the wrong
mode is set
The required command enable
signal is missing.
Eliminate and acknowledge all
queued errors and then enable
the axis for the relevant mode.
40005
8043 Illegal command
parameter value or
preset value
One or several values at the
input parameters of the FB for
the command, or the preset
values in relevant parameters
are illegal.
Check the command and adjust
illegal parameters. Note the
current preset values.
30001
8045 Illegal command with
current status
• A command of higher
priority is busy (e.g.
MC_Stop).
• The technology object is
disabled or not ready.
• Received measurement
command when homing
Acknowledge all queued errors of
the technology object.
Wait for the initialization of the
technology object (after restart).
Enable the technology object.
Disable MC_Stop.
Do not start any measuring
commands in the homing phase.
30006, 30009
8046 The drive does not
support this command
The connected drive does not
support this type of command,
for example, a certain homing
mode.
Check and adjust the drive
configuration data and settings.
50012
8047 Can not acknowledge
this error
It is not possible to reset the
error with FB MC_Reset.
Examples:
• An axis has been brought
to standstill, and the error
causing this can not be
acknowledged.
• Further errors occur in the
acknowledgment or restart
phase.
Eliminate all causes of error and
retry to acknowledge. Please note
that you must acknowledge
particular errors by cycling power.
30007
8048 Unable to restart The object is busy or a queued
error prevents restart.
Eliminate and acknowledge all
queued errors and disable the
object.
20012