Technical data

Technology DBs
CPU 317T: Technology Functions
A5E00251798-03
7-43
ErrorID
Error message Possible causes To correct or avoid errors Interrupts in
S7T Config*
Synchroni-
zation object
Interrupts in
S7T Config*
Synchroni-
zation axis
8074 The leading axis is
not configured for
synchronous
operation
In the configuration of
the following axis, the
axis connected at the
"Master" terminal was
not defined as leading
axis.
The leading axis is not
enabled (applies only
for the external
encoder).
The leading axis is
operated with velocity
control.
Adjust the configuration of the
following axis or use the
configured leading axes.
Operate the leading axis in
position-controlled mode or
enable it.
50101,
50102
8077 Deactivation of
synchronous
operation aborted
Deactivation of
synchronous operation
was rejected, because the
current synchronous
operation type (gear/cam
gear) does not agree with
the deactivation type.
Deactivate camming with
MC_CamOut and gearing
with MC_GearOut, or use
global instructions (MC_Halt,
MC_Stop, ...)
50005
8078 Superimposing
synchronism is not
possible
Superimposing
synchronism was set for
the axis in the experts list.
Adjust the settings in the
experts list
8082 Illegal Zero value in
parameter
A command was passed
alongside with a
Zero
parameter. This value
must always be unequal
to
Zero.
Check the transferred
parameters, preset values
and, in particular, the dynamic
and limit values. (e.g. max.
velocity, or acceleration for
positioning)
40006,
40007,
40008,
40009,
40010,
40011
40006,
40007,
40008,
40009,
40010,
40011
8085 Illegal limit switch
parameters
Implausible position
values for the SW limit
switch. One of the values
violates the range, or the
start value exceeds the
end value. The latter may
occur if the order is
neglected when the
parameters are changed.
Adjust the setting of the SW
limit switch. After the first
change of the position, the
position value of the positive
switch must be higher than
that of the negative switch.
40104
8090 Illegal Zero
parameter
Reserved error 40122,
40123
8091 Error in pressure
control
Reserved error 50014
8092 Error in force limit
monitoring
Reserved error 50109,
50110