Technical data
Technology DBs
CPU 317T: Technology Functions
A5E00251798-03
7-41
ErrorID
Error message Possible causes To correct or avoid errors Interrupts in
S7T Config*
Synchroni-
zation object
Interrupts in
S7T Config*
Synchroni-
zation axis
8042 Illegal change of
axis status
The command for
changing
the axis status was
rejected, because:
• The current
phase in operation is
not completed yet.
• A mode transition is
not possible.
Repeat the command
Reset first.
40001
8043 Invalid command
parameter
or preset value
One or several values at
the input parameters of
the FB for the command,
or preset values in
relevant parameters are
illegal.
Check the command and
adjust illegal parameters.
Note the current preset
values.
30001,
50107
30001
8045 Illegal command
with current status
• A command of higher
priority is busy (e.g.
MC_Stop).
• The technology object
is disabled or not
ready.
• Received
measurement
command when
homing
Acknowledge all queued
errors of the technology
object.
Wait for
the initialization of the
technology object (after
restart).
Enable the technology object.
Disable MC_Stop.
Do not start any measuring
commands during homing.
30006 30006,
30009
8046 The drive does not
support this
command
The connected drive does
not support this type of
command, for example, a
certain homing mode.
Check and adjust the drive
configuration data and
settings.
50012
8047 Can not
acknowledge this
error
It is not possible to reset
the error with FB
MC_Reset. Examples:
• An axis has been
brought to standstill,
and the error causing
this can not be
acknowledged.
• Further errors occur in
the acknowledgment
or restart phase.
Eliminate all causes of error
and retry to acknowledge.
Please note that you must
acknowledge particular errors
by cycling power.
30007 30007
8048 Unable to restart The object is busy or a
queued error prevents
restart.
Eliminate and acknowledge
all queued errors and disable
the object.
20012 20012