Technical data
Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-215
6.6.2 FB 406 MC_ReadSysParameter - Reading parameters
Valid for firmware version V3.1.x of the integrated technology
Purpose
• The technology function "MC_ReadSysParameter" returns selected
parameters of a technology object, for example, of an axis or cam.
• The valid actual value is indicated at the restart parameters.
• The result is output at the relevant output parameter, depending on the
parameter type. In this case the other outputs return the a 0 value.
• At input parameter Index you can define which of the multiple parameters of
the project you want to access. Multiple parameters exist in these areas:
- Data records (Dataset_1 to Dataset_16)
- Encoders (Encoder_1 to Encoder_8)
- Synchronization objects (1 for synchronization object, 2 for superimposing
synchronization object)
Applicable to
• The parameter defined by the parameter number and the index must be
available in the system.
Overriding commands
An MC_ReadSysParameter command can not be canceled by any other
command.
An MC_ReadSysParameter command does not cancel any other commands.
Input parameters
Parameter Data type Start value Description
Axis INT 0 Number of the technology DB
Execute BOOL FALSE Command parameter value at the positive edge
ParameterNumber INT 0 Number of the parameter to be read
Index INT 0 Parameter field number (2 for data_set_2, for
example)