Technical data

Technology functions
CPU 317T: Technology Functions
6-212 A5E00251798-03
Requirements for restart
A restart is only possible when the relevant technology object is disabled, or
not busy, or not in use by another application.
Warning
Set Restart = FALSE if you only want to clear the errors at a technology object.
Re-initialization of a technology object (Restart = TRUE) may take several 100
milliseconds. The technology object is not available for the duration of this process.
Overriding commands
MC_Reset
MC_Reset (Restart=FALSE)
MC_Reset (Restart=FALSE)
MC_Home
MC_ChangeDataset
(Cancellation relationships are shown in read direction)
An MC_Reset with Restart = TRUE can not be canceled
Input parameters
Parameter Data type Start value Description
Axis INT 0 Number of the technology DB
Execute BOOL FALSE Start of the command at the positive edge
Restart BOOL FALSE FALSE: Acknowledge error
TRUE: Restart - Re-initialization and application
of modified configuration parameters