Technical data

Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-119
Output parameters
Parameter Data type Start value Description
InSync BOOL FALSE TRUE: Base cam synchronism reached
Busy BOOL FALSE TRUE: Command is busy
CommandAborted BOOL FALSE TRUE: The command was aborted by another
command or by an error during command
execution.
If ErrorStatus of the technology DB
does not indicate an error, the
command was canceled by a subsequent
command.
If ErrorStatus reports an error, an error at
the TO occurred during command
execution and has caused cancellation of
the command.
Error BOOL FALSE
TRUE: Command initiation
with error.
The command is not
executed; the cause is found in the
ErrorID.
FALSE: Command initiation
without error
ErrorID WORD 0
ErrorID of the Error output parameter.
Recommendation for starting cam synchronism
1. Move the following axis to position XS.
2. Move the leading axis to position X
m, whereby XS = cam value (Xm)
3. Start the "MC_CamIn" technology function.