Technical data

Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-19
6.2.3 FB 404 MC_Stop - Stop axes / prevent new motion commands
Purpose
The "MC_Stop" technology function stops all motions and ramps the axis down
to standstill. The standstill position is not defined.
The command is done (Done = TRUE), when the axis is in standstill and
Execute = FALSE is set, i.e. as long as Execute = TRUE is set, startup of the
axis is inhibited. This also applies if the axis was locked in the meantime with
MC_Power and then re-enabled.
The dynamic response within the motion stop operation is determined at the
input parameters Jerk and Deceleration.
Applicable to
Velocity axes
Positioning axes
Synchronization axes
Requirements
For dynamic stop, the axis must be enabled for position or velocity control. The
axis can not be ramped down dynamically when it is in following mode or
locked state!